7.50. SETXMAX Control procedure
7.50.1. SETXMAX Control
CMD Data1 Data2 Data3 Data4 Data5
Command
(0xF5)
Target
(0x88)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x3F)
Value
Command (0xF5) : Start bit
Target (0x88) : Set bit
Monitor ID (0x00) : Default value -> 0x00
CMD (0xFE) : command data
Parameter(0x3F) : SETXMAX parameter
Value: 1 ~ 3 (range)
7.50.2. Current SETXMAX state read
CMD Data1 Data2 Data3 Data4
Command
(0xF4)
Target
(0x89)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x3F)
Command (0xF4) : Start bit
Target (0x89) : Get bit
Monitor ID (0x00) : Default value -> 0x00
CMD(0xFE) : command data
Parameter (0x3F) : SETXMAX parameter
CMD Data1
Command
(0xF1)
Value
Command (0xF1) : Start send bit
Value : Current SETXMAX getting value
1 ~ 3 (range)