74
7.48. SETX Control procedure
7.48.1. SETX Control
CMD Data1 Data2 Data3 Data4 Data5
Command
(0xF5)
Target
(0x88)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x3D)
Value
Command (0xF5) : Start bit
Target (0x88) : Set bit
Monitor ID (0x00) : Default value -> 0x00
CMD (0xFE) : command data
Parameter(0x3D) : SETX parameter
Value: 0 ~ 2 (range)
7.48.2. Current SETX state read
CMD Data1 Data2 Data3 Data4
Command
(0xF4)
Target
(0x89)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x3D)
Command (0xF4) : Start bit
Target (0x89) : Get bit
Monitor ID (0x00) : Default value -> 0x00
CMD(0xFE) : command data
Parameter (0x3D) : SETX parameter
CMD Data1
Command
(0xF1)
Value
Command (0xF1) : Start send bit
Value : Current SETX getting value
0 ~ 2 (range)