39
7.16. USERRED Control procedure
7.16.1. USERRED Control
CMD Data1 Data2 Data3 Data4 Data5
Command
(0xF5)
Target
(0x88)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x0F)
Value
Command (0xF5) : Start bit
Target (0x88) : Set bit
Monitor ID (0x00) : Default value -> 0x00
CMD (0xFE) : command data
Parameter(0x0F) : USERRED parameter
Value: 0 ~ 100 (range)
7.16.2. Current USERRED state read
CMD Data1 Data2 Data3 Data4
Command
(0xF4)
Target
(0x89)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x0F)
Command (0xF4) : Start bit
Target (0x89) : Get bit
Monitor ID (0x00) : Default value -> 0x00
CMD(0xFE) : command data
Parameter (0x0F) : USERRED parameter
CMD Data1
Command
(0xF1)
Value
Command (0xF1) : Start send bit
Value : Current USERRED getting value
0 ~ 100 (range)