NEC LCD8205 Manuale Utente Pagina 75

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 79
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 74
75
7.49. SETY Control procedure
7.49.1. SETY Control
CMD Data1 Data2 Data3 Data4 Data5
Command
(0xF5)
Target
(0x88)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x3E)
Value
Command (0xF5) : Start bit
Target (0x88) : Set bit
Monitor ID (0x00) : Default value -> 0x00
CMD (0xFE) : command data
Parameter(0x3E) : SETY parameter
Value: 0 ~ 2 (range)
7.49.2. Current SETY state read
CMD Data1 Data2 Data3 Data4
Command
(0xF4)
Target
(0x89)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x3E)
Command (0xF4) : Start bit
Target (0x89) : Get bit
Monitor ID (0x00) : Default value -> 0x00
CMD(0xFE) : command data
Parameter (0x3E) : SETY parameter
CMD Data1
Command
(0xF1)
Value
Command (0xF1) : Start send bit
Value : Current SETY getting value
0 ~ 2 (range)
Vedere la pagina 74
1 2 ... 70 71 72 73 74 75 76 77 78 79

Commenti su questo manuale

Nessun commento