14.5.4 Cautions When Supply Voltage Raised
When supply voltage is raised, careful attention must be given to points (1) and (2) below.
(1) When V
DD raised from power-on clear voltage
When V
DD is raised, it must be raised to 3.5 V or greater, once.
This is shown in Fig. 14-7.
As shown in Fig. 14-7, when a voltage under 3.5 V is applied when V
DD is turned on in a program that uses
clock-stop to back up V
DD at 2.2 V, for example, the power-on clear signal continues to be output and the
program does not run.
Since the device output port outputs an undefined value, the supply current increases, according to the
situation, reducing the back-up time with a battery considerably.
Fig. 14-7 Caution When VDD Raised
5 V
0 V
Operation stopped
X
OUT
V
DD
CE
Power-on
clear signal
Timer carry FF
set pulse
3.5 V
2.2 V
Opera-
tion
stopped
Halt state
50 ms
Normal operation Back-up
Since the values of the output
ports, etc. are undefined during
this period, the current drain
may increase.
During this period,
initialization is per-
formed, then the
clock is stopped.
Power-on reset
Program start
STOP 0000B
Power-on
clear voltage
Vedere la pagina 181