7-18 Advanced Features
MA4000 Installation Manager User Guide - Revision 6
Step 1 Choose the LCR number to be programmed and select the Edit button.
Figure 7-15 displays
.
To create a new LCR entry, select the New button.
Figure 7-15
Edit System Features
Step 2 Enter the Call Pattern information. The system will then use this pattern
to match a user's dialed digits and invoke LCR for the call.
Step 3 Select the number of digits from the Maximum Necessary Digits drop-
down field that the system will scan. The Maximum Necessary Digits
number is the number of digits (from left to right) the system waits before
sending a call for further processing. If the number contains fewer than
the Maximum Necessary Digits, the system waits as follows:
—Interdigit Timeout (typically 10 seconds) x the missing digits number
—For example, if the Ma
ximum Necessary Digits is 12 and the system
receives 10 digits, it waits 2 x 10 = 20 seconds before processing the
call.
2 (numDigits missing) x 10 (interdigit timeout) = 20