NEC Express5800/R120f-1M Manuale Utente

Navigare online o scaricare Manuale Utente per Array per dischi NEC Express5800/R120f-1M. NEC Express5800/R120f-1M Appendix Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 26
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Appendix B : raidcmd Command Reference
This chapter describes commands of the raidcmd.
Notice on specifying Physical Device number
The -p option for raidcmd is used to specify the Physical Device number.
Be sure to execute the following command to check the Physical Device number before you use the option.
The format of Physical Device number is e<enclosure-number>s<slot-number>.
[Format]
raidcmd
cc
[Overview]
Starts or stops Consistency Check.
[Format]
raidcmd
cc
-c={all|<controller> -l={all|<logicaldrive>}} -op={start|stop|force}
Command Parameter
Description
-c={all|<controller>}
Specify the RAID Controller to be processed.
all : all of RAID Controllers
<controller> : RAID Controller Number
-l={all|<logicaldrive>}
Specify the Logical Drive to be processed.
all : all of Logical Drives on the RAID Controller specified by -c
<logicaldrive> : Logical Drive Number
-op={start|stop}
Specify whether Consistency Check is started or stopped.
start : Starts Consistency Check(Automatic Stop Enabled)
stop : Stops Consistency Check.
force : Starts Consistency Check. (Automatic Stop Disabled)
For details of Automatic Stops of Consistency Check, see "Monitoring Medium Errors to see
if they occur frequently" of "Universal RAID Utility User's Guide".
[Description]
Starts Consistency Check of the specified Logical Drive or stops Consistency Check executed for the specified
Logical Drive.
Don't use -l when specified -c with "all".
[Condition]
Allow to start Consistency Check to Logical Drive with the following situation.
- RAID Controller has the function of Consistency Check.
- The RAID Level of the Logical Drive is not 0.
- The status of the Logical Drive is [Online].
- It is not running Consistency Check to the Logical Drive now.
Allow to stop Consistency Check to Logical Drive with the following situation.
- RAID Controller has the function of Consistency Check and stopping it.
- The RAID Level of the Logical Drive is not 0.
- The status of the Logical Drive is [Online] or [Degraded].
- It is running Consistency Check to the Logical Drive now.
1
Vedere la pagina 0
1 2 3 4 5 6 ... 25 26

Sommario

Pagina 1

Appendix B : raidcmd Command Reference This chapter describes commands of the raidcmd. Notice on specifying Physical Device number The -p option for

Pagina 2

mkldc [Overview] Creates a Logical Drive with advanced parameter settings. [Format] Making a Logical Drive having RAID Level of RAID 0, RAID 1, RAID

Pagina 3

Command Parameter Description -rl={0 | 1 | 5 | 6 | 10 | 50 | 60 } Specify the RAID Level of the Logical Drive to be created as follows: 0 : RAID 0 1 :

Pagina 4

mklds [Overview] Creates a Logical Drive with simple parameter settings. [Format] raidcmd mklds -c=<controller> -p=<physicaldevice1>, <

Pagina 5

mkscd [Overview] Creates an SSD Cache Drive. [Format] raidcmd mkscd -c=<controller> -p=<physicaldevice1> [,<physicaldeviceX>, ... ,

Pagina 6

oplist [Overview] Displays the list of operations performed in a RAID Controller and their progresses. [Format] raidcmd oplist [Description] Displays

Pagina 7

optctrl [Overview] Allows you to set optional parameters of a RAID Controller. [Format] raidcmd optctrl -c=<controller> {-ip={high | middle | l

Pagina 8

optld [Overview] Allows you to set optional parameters of a Logical Drive. [Format] raidcmd optld -c=<controller> -l=<logicaldrive> -cm={

Pagina 9

property [Overview] Displays the properties of RAID Controllers, Disk Arrays, Logical Drives and/or Physical Devices. [Format] raidcmd property –tg=

Pagina 10

rebuild [Overview] Starts or stops Rebuild. [Format] raidcmd rebuild -c=<controller> -p=<physicaldevice> -op={start|stop} Command Parame

Pagina 11

refresh [Overview] Refreshes the battery connected to the RAID Controller [Format] raidcmd refresh -c=<controller> [-y] Command Parameter Desc

Pagina 12

ccs [Overview] Starts Consistency Check of Logical Drives in the RAID Controllers in which Patrol Read is disabled or not supported. [Format] raidcmd

Pagina 13

refreshs [Overview] Refreshes the batteries connected to the RAID Controllers which support the Refresh Battery function. [Format] raidcmd refreshs [

Pagina 14

rescan [Overview] Update the RAID System management information of the Universal RAID Utility. [Format] raidcmd rescan [Description] This command col

Pagina 15

runmode [Overview] Changes the RAID System Management Mode of the raidcmd. [Format] raidcmd runmode [-md={a|s}] Command Parameter Description [-md={

Pagina 16

sbuzzer [Overview] Stops the Buzzer on a RAID Controller. [Format] raidcmd sbuzzer -c=<controller> Command Parameter Description -c=<contro

Pagina 17

slotlamp [Overview] Turns on or off the DISK lamp of the computer or enclosure in which Physical Devices are installed. [Format] raidcmd slotlamp -c=

Pagina 18

stspd [Overview] Changes the status of a Physical Device to online or failed forcibly. [Format] raidcmd stspd -c=<controller> -p=<physicalde

Pagina 19

(no command) [Overview] Displays the version of Universal RAID Utility and the RAID System Configuration as a Tree View. [Format] raidcmd [Descriptio

Pagina 20

delld [Overview] Deletes a Logical Drive. [Format] raidcmd delld -c=<controller> -l=<logicaldrive> [-y] Command Parameter Description -c

Pagina 21

delscd [Overview] Deletes an SSD Cache Drive. [Format] raidcmd delscd -c=<controller> -l=<logicaldrive> [-y] Command Parameter Descripti

Pagina 22

econfig [Overview] Configures a RAID System with a RAID Controller easily. [Format] raidcmd econfig [Description] Executes easy configuration which c

Pagina 23

fwup [Overview] Updates the RAID Controller firmware. [Format] raidcmd fwup –c= <controller> -f=<firmware image filepath> [-ocr={yes|no}]

Pagina 24

help [Overview] Displays the help of raidcmd. [Format] raidcmd help <subcommand> Command Parameter Description <subcommand> Specify the

Pagina 25

hotspare [Overview] Makes or removes a Hot Spare. [Format] raidcmd hotspare -c=<controller> -p=<physicaldevice> -mr={make [-a=<diskarr

Pagina 26 - (no command)

init [Overview] Starts or stops Initialize. [Format] raidcmd init -c=<controller> -l=<logicaldrive> -op={start|stop} [-im={full|quick}] [

Commenti su questo manuale