Control Commands for NEC Projector (Basic) Rev 5.16.11a
Copyright (C) NEC Display Solutions, Ltd. 2002-2011
----------------------------------------------------------------------
Updated on May 16, 2011
----------------------------------------------------------------------
This file contains information about NEC projector control commands.
Model Name
GT60 : GT5000/GT6000 Series
GT50 : GT1150/GT2150 Series
HT : HT1000/HT1100 Series
HT10 : HT410/HT510 Series
LT180 LT180
LT30 : LT25/LT30/LT35 Series
LT : LT220/LT240/LT240K/LT260/LT260K/LT245/LT265 Series
LT80 : LT280/LT380 Series
MT70 : MT860/MT1060/MT1065/MT1075 Series
NP60 : NP40/NP50/NP60 Series
NP62 : NP41/NP61/NP62 Series
NP1000 : NP1000/NP2000 Series
NP3150 : NP1150/NP2150/NP3150/NP3151W Series
NP4000 : NP4000/NP4001 Series
NP905 : NP905/NP901W/VT800 Series
NP600 : NP300/NP400/NP500/NP500W/NP500WS/NP600/NP600S Series
VT : VT770 Series
VT70 : VT37/VT47/VT480/VT57/VT570/VT575/VT670/VT676 Series
VT80 : VT48/VT480/VT580 Series
VT90 : VT49/VT490/VT590/VT595/VT695 Series
VT700 : VT700
WT : WT600/WT610/WT615 Series
NP4100 : NP4100/NP4100W Series
NP3250 : NP1250/NP2250/NP3250/NP3250W Series
NP610 : NP310/NP410/NP410W/NP510/NP510W/NP510WS/NP610/NP610S Series
NP2200 : NP1200/NP2200 Series
NP216 : NP110/NP115/NP215/NP216 Series
NP64 : NP43/NP64 Series
M300 : M260X/M260W/M300X/M300W Series
P420 : P350X/P350W/P420X Series
U300 : U300X/U310W Series
V300 : V260/V260X/V200X Series
PA600 : PA600X/PA550W/PA500U/PA500X
Vedere la pagina 0
1 2 3 4 5 6 ... 57 58

Sommario

Pagina 1

====================================================================== Control Commands for NEC Projector (Basic) Rev 5.16.11a Copyright (C) NEC Di

Pagina 2

00H : Start is not requested 01H : Cannot process due to storing 02H : Exceeds the total number of blocks required

Pagina 3

==================================================================== 4. List of Commands -----------------------------------------------------------

Pagina 4

07 : GT5000 08 : LT240K/LT260K 09 : GT6000 10 : HT1100 11 : VT770 12: HT410/HT510 (HT10 Series) 13 : LT245/LT265 14 : LT280/LT380 15 : LT180

Pagina 5

Meaning of Symbols--------------------------------------------------------------------* Supported! Is available depending on model's version-

Pagina 6

Command Name 1 2 3 4 5 6 7 8 9 10111213141516171819202122232428006. RUNNING SENSE ***********-**-- -**- --***007

Pagina 7

In case of V300 series 20H In case of VT series 40H In case of NP600 series 40H In case of NP610 series 40H I

Pagina 8

Bit 7: Power On/Off processing 0 = No execution (Normal condition) 1 = During execution

Pagina 9

01H: Power On DATA05 Cooling processing 00H: No execution (Normal condition) 01H: During

Pagina 10

DATA32 Freeze Status (!2) 00H : OFF 01H : ON FFH : Not Supported DATA33 Test pattern display 1

Pagina 11

00H : No execution (Normal condition) 01H : During execution DATA69 Status of operation

Pagina 12

====================================================================== Contents 1. Projector Control 2. Connection Method 3. Interface Condit

Pagina 13

Data01 Data70 Data7101H 00H 03H MT1060/MT106501H 01H 03H MT86001H 02H 03H MT107501H 00H 06H NP1000/NP200002H 00H 03H LT240/LT26002H 01H 03H LT22002H 0

Pagina 14

DATA72 PC Card insertion 00H : Not inserted 01H :

Pagina 15

009. ERROR STATUS REQUEST ********************************************************************** Function: This command acquires the error informatio

Pagina 16 - 1 .. 254 NP216

Supplement: (!) LT/LT80/HT: "None" 015. POWER ON ********************************************************************** Function: This

Pagina 17

DATA02 Switching number --------------------------------------------------------- When the switching object is the &qu

Pagina 18

Response: At the time of a success 22H 03H 01H xxH 01H DATA01 CKS (*1) (*2) (*3) Data Por

Pagina 19

022. SOUND MUTE ON ********************************************************************** Function: This command mutes the sound. Command: 02H

Pagina 20

025. ONSCREEN MUTE OFF ********************************************************************** Function: This command cancels the blanking of the on

Pagina 21

DATA03 : 00H (direct settings) 01H (increment/decrement) DATA04 : lower data (8bit) DATA05 : upper data

Pagina 22

------------------------------------------------------------------- DATA01 .. 02 Results 0000H : Normal 0000H

Pagina 23

(!2) Only the M300 series is compatible. [P350X/P350W/P420X Series]STANDBY MODE: "POWER-SAVING"Control CommandSerial portWired LAN portWirel

Pagina 24

DATA04 DATA05Aspect Ratio 4:3 (Window) 00H 00HAspect Ratio Normal / Auto (NP600, NP610, NP2200, NP62, NP64, NP216, P420, PA600, U300, V300 Series) 00

Pagina 25

Supplement: (!) Lamp Hour Meter This is the timer for normal lamp mode conversion. Lamp Timer Acquisition Examples DATA83 DATA84 DATA85 DA

Pagina 26

2) Punch in DATA12 DATA11 DATA10 DATA09 (006DDD00) 3) Change from HEX to Decimal - value will change to 7200000 seconds Lamp remaining ti

Pagina 27

to appear (in terms of Eco mode values) 10H : Remaining time until inhibition of lamp usage

Pagina 28

Function: This command acquires the information on the projector lamp. Command: 03H 9BH 00H 00H 03H DATA01 DATA02 DATA03 CKS

Pagina 29

Lamp Use Warning Starting Time 2000[H] Model. X = 100 - ((2100 * 100) / 2000) = -5[%] (!2) Lamp Hour Meter This is the timer f

Pagina 30

00H : Normal 01H : Error Response: At the time of a failure A3H B1H 01H xxH 02H DATA01 DATA02 C

Pagina 31

01H : Error Response: At the time of a failure A3H B1H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2

Pagina 32

Key number DATA01 DATA02 Key name --------------------------------------------

Pagina 33

81 51H 00H S-VIDEO1 (!!) 82 52H 00H S-VIDEO2

Pagina 34

(1) (2) (3-1) (3-2) (3-3) (3-4)GT5000/GT6000 Yes Yes Yes Yes Yes NoGT1150/GT2150 Yes No Yes Yes Yes NoHT410/HT510 Yes No No No No NoHT1000/HT1100 Yes

Pagina 35

Command example: * Sending the AUTO key code 02H 0FH 00H 00H 02H 05H 00H 18H * Sending the AUTO (SHORT) key code 02H 0FH 00H 00H 0

Pagina 36

Function: This command acquires the Carbon Saving values on the projector. Command: 03H 9AH 00H 00H 01H DATA01 CKS

Pagina 37

Function: This command acquires the adjustment values. Command: 03H 04H 00H 00H 03H DATA01 .. DATA03 CKS

Pagina 38

(! ) Acquirement itemsDATA01 DATA02 Acquirement name00H 00H Picture / Brightness01H 00H Picture / Contras

Pagina 39

4CH 07H Color Correction / Yellow4CH 08H Color Correction / Magenta4CH 09H Color Correction / Cyan4CH 0AH Color Correction / White4DH 00H Through4EH 0

Pagina 40

077. MUTE CONTROL ********************************************************************** Function: This command controls the mute of picture, sound a

Pagina 41

DATA01 DATA02 DATA0301H 00H 03H MT1060/MT106501H 01H 03H MT86001H 02H 03H MT107501H 00H 06H NP1000/NP200002H 00H 03H LT240/LT26002H 01H 03H LT22002H 0

Pagina 42

DATA04 Sound function 00H : Not available 01H : Available DATA05 Calendar function

Pagina 43

01H : Connected DATA09 .. 16 Reserved Response: At the time of a failure A0H 85H 01H xxH 02H DATA01 DATA02 CKS

Pagina 44

DATA06 Test pattern display 00H : No display(Normal condition) 01H : Displaying DATA07 ..08 Reserved

Pagina 45

Before making connections, set the standby mode of the projector to "NORMAL" or "Idol mode". The projector cannot use the c

Pagina 46

078-5. MODEL NAME REQUEST ********************************************************************** Function: This command acquires the model name of

Pagina 47

[079. FREEZE CONTROL] ********************************************************************** Function: This command controls the freeze. Command:

Pagina 48

Command: 03H B0H 00H 00H 02H DATA01 DATA02 CKS Data Portion Contents ---------------------------------------------------------------

Pagina 49

02H : BOTTOM-LEFT 03H : BOTTOM-RIGHT if DATA02 is SOURCE(02H) 00

Pagina 50

111. AUTO ADJUST EXECUTE2 ********************************************************************** Function: This command executes the Auto Adjust.

Pagina 51

DATA02 DATA03 DATA13 DATA1400H 01H 00H 03H MT1060/106500H 01H 02H 03H MT86000H 01H 02H 03H MT107500H 01H 00H 06H NP1000/NP200000H 02H 00H 03H LT240/LT

Pagina 52

DATA15 ... 16 Reserved Response: At the time of a failure A0H BFH 01H xxH 02H DATA01 DATA02 CKS

Pagina 53

09H : SLOT2 0AH : SLOT3 0BH : SLOT4 0CH : DIGITAL2

Pagina 54

====================================================================== 6.1. Response ----------------------------------------------------------------

Pagina 55

The PC CONTROL connector is a D-SUB 9-pin connector. 1 2 To TxD of PC 3 To RxD of PC 4 5 To GND of PC 6 7 To CTS of

Pagina 56

Command : This sets an identification data assigned to each command to send it. ( See each command description.) Response : This returns the 6th

Pagina 57

basis Broadcast notification is recommended. * When the controller is connected with multiple projectors To control a certain projector, use &q

Pagina 58

4-2. Data portion of response ********************************************************************** For ACK This returns ACK without adding data