Nec 140He Manuale Utente Pagina 264

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 263
9-6
change cable connection. However, to use the hard disk drives in a disk array configuration using the optional RAID
controller, you need to use a separately priced SCSI cable. Remove the cable that is connected between the SCSI Ch-A
connector and the hard disk drives cage, and connect the separately priced SCSI cable to the connector between the hard
disk drives cage and the disk array controller.
In the disk array configuration, use the same model of hard disk drives.
Installation
Install a hard disk drive as follows. This procedure applies to all the slots.
NOTE: In RAID1 or RAID5 configuration, the hard disk drive can be installed or removed
while the server is being powered.
IMPORTANT: In a disk array configuration, use the same model of hard disk drives.
1. See the section "Preparing for Installation and Removal" described earlier to prepare (except for disk array
configuration).
2. Unlock the front door with the security key, and open the front door.
3. Locate the slot in which you are going to install a hard disk drive.
The server has five slots. The SCSI IDs assigned to the slots are all determined (SCSI ID 0 to ID 4 from right
to left).
4. Remove the empty drive carrier.
Vedere la pagina 263